CONTENTS | |
I. Specifications........................................................... | 4 |
A. Nameplate Rating ..................................................... | 4 |
1. KM-501MAH (air-cooled)............................................. | 4 |
2. KM-501MWH (water-cooled).......................................... | 5 |
3. KM-501MRH (remote air-cooled) ...................................... | 6 |
B. Dimensions / Connections .............................................. | 7 |
1. KM-501MAH...................................................... | 7 |
2. KM-501MWH...................................................... | 8 |
3. KM-501MRH...................................................... | 9 |
II. Installation and Operating Instructions ...................................... | 10 |
A. Checks Before Installation ............................................. | 10 |
B. How to Remove Panels................................................ | 10 |
C. Location ........................................................... | 11 |
D. Setup.............................................................. | 11 |
E. Electrical Connection ................................................. | 12 |
F. Installation of Remote Condenser Unit.................................... | 13 |
1. Checks Before Installation........................................... | 13 |
2. Location......................................................... | 13 |
3. Setup ........................................................... | 14 |
4. Electrical Connection............................................... | 15 |
5. Stacking Condenser Unit............................................ | 16 |
G. Water Supply and Drain Connections..................................... | 17 |
H. Final Checklist ...................................................... | 19 |
I. Startup............................................................. | 20 |
J. Preparing the Icemaker for Long Storage.................................. | 21 |
III. Cleaning and Maintenance Instructions ..................................... | 23 |
A. Cleaning Instructions ................................................. | 23 |
1. Cleaning Procedure................................................ | 24 |
2. Sanitizing Procedure - Following Cleaning Procedure ..................... | 25 |
B. Maintenance........................................................ | 26 |
MODEL NUMBER | KM-501MAH | |
SERIAL NUMBER | 115-120/60/1 | |
AC SUPPLY VOLTAGE | ||
COMPRESSOR | 115-120V 11RLA 50LRA | |
PUMP | 120V 0.5FLA 10W | |
FAN | 120V 0.85FLA 50W | |
OTHER | 115-120V 0.15A | |
MAXIMUM FUSE SIZE | 20 | AMPS |
MAX. HACR BREAKER(USA ONLY) | 20 | AMPS |
MAX. CIRC. BREAKER (CANADA ONLY) | 20 | AMPS |
MINIMUM CIRCUIT AMPACITY | 20 | AMPS |
DESIGN PRESSURE | HI-467PSI LO-206PSI | |
REFRIGERANT | 404A 1 LB 10 OZ |
MODEL NUMBER | KM-501MWH | |
SERIAL NUMBER | 115-120/60/1 | |
AC SUPPLY VOLTAGE | ||
COMPRESSOR | 115-120V 10.5RLA 50LRA | |
PUMP | 120V 0.5FLA 10W | |
FAN | --- --- --- | |
OTHER | 115-120V 0.15A | |
MAXIMUM FUSE SIZE | 20 | AMPS |
MAX. HACR BREAKER(USA ONLY) | 20 | AMPS |
MAX. CIRC. BREAKER (CANADA ONLY) | 20 | AMPS |
MINIMUM CIRCUIT AMPACITY | 20 | AMPS |
DESIGN PRESSURE | HI-427PSI LO-206PSI | |
REFRIGERANT | 404A 15 OZ |
MODEL NUMBER | KM-501MRH | |
SERIAL NUMBER | 115-120/60/1 | |
AC SUPPLY VOLTAGE | ||
COMPRESSOR | 115-120V 11RLA 50LRA | |
PUMP | 120V 0.5FLA 10W | |
FAN REMOTE | 120V 3A MAX | |
OTHER | 115-120V 0.9A | |
MAXIMUM FUSE SIZE | 20 | AMPS |
MAX. HACR BREAKER(USA ONLY) | 20 | AMPS |
MAX. CIRC. BREAKER (CANADA ONLY) | 20 | AMPS |
MINIMUM CIRCUIT AMPACITY | 20 | AMPS |
DESIGN PRESSURE | HI-467PSI LO-206PSI | |
REFRIGERANT | 404A |
3. KM-501MRH | Unit: inches (mm.) |
Fig. 5 | Fig. 6 |
CLOSED POSITION | OPEN POSITION |